1. Is it possible for CDS4004802 to adjust the output voltage from 2VDC to 1VDC?
Answer : When using the CDS4004802 in the range of 1-1.2V, there is a possibility that the overshoot occur. And then the overshoot is about 140mV. |
2. For SUCW1R5 and SUCW3 dual outputs converter, if the two loading isn't same, ie. one is bigger, another one is smaller. What will happen on the output voltage and current?
Answer : Output voltage will be changed by load factor because SUCW series is dual output type.
In case of dual output, one voltage decreases by large current, and another output voltage increases.
We call this characteristic "cross regulation".
The changed value has not decided, however it may be +/- 5% approximately. |
|